Home Contact us Sitemap
 
 
Technical Specification for Powermat DMC / SMC / Epoxy
Properties Units Test Methods
(ASTM)
Values
SMC DMC EPOXY
PHYSICAL      
Specific Gravity   D-792 1.7 1.9 1.6 - 2.0
Glass Contents % N.A 25 15 -
Water Absorption (24 hrs) % D-570 0.2 0.15 0.04 - 0.1
MECHANICAL
Tensile Strength Kgf/Cm2 D-638 700 400 750 - 400
Flexural Strength Kgf/Cm2 D-790 1550 900 800
Compressive Strength Kgf/Cm2 D-695 1800 1500 1600
Impact Strength Izod

J/m

D-265 600 250 -
ELECTRICAL
Dielectric Strength

KV/mm

D-149 12 10 13
Tracking Index

Volts

BS-5901 +600 +600 +600
ARC Resistance

Secs.

D-495 +180 +180 +180
FLAMMABILITY   UL-94 Self Extinguishing V-0 Self Extinguishing
TOLERANCE CHART
DIM (mm)

TOLERANCE ( ± )

1-15 0.25 mm
16-50 0.5 mm
51-100 1.0 mm
101-250 1.5 mm
250 & above 2 mm

The above values are for the standard formula followed by the company but we have facilities for manufacturing SMC, DMC, EPOXY according to the customer requirements. For technical notes of DMC, SMC, Busbar Supports, Short Circut and Fauld Level calculations please ask for broucher No. T-02/05

( SMC = Sheet Moulding Compound )
( DMC = Dough Moulding Compound )

All data given has been determined carefully at the company's test lab, with the variety of purpose for which the products are used, and the methods and application technique employed. However the data and information are given only as a guide, and are not binding. No guarantee of their authenticity can therefore be assumed in all situations and the company reserves the right to modify features without prior notice in view of continued improvements.
 
© Powercam Electricals Pvt Ltd. 2006-2007